Every glove catalogue has one: a wall of chemicals down the left, glove materials across the top, and a grid of letters or colors in between. A glove chemical compatibility chart looks like the simplest document in safety — find your chemical, read the letter, done. In reality it is a compressed summary of laboratory permeation testing, and reading it naively is how facilities end up with gloves that fail twenty minutes into an eight-hour task. This guide explains what those ratings actually encode, what they leave out, and how to use a chart the way a safety professional does.

What the Letters and Colors Actually Mean
Most charts grade each chemical–material pair on a four- or five-step scale — Excellent / Very Good / Good / Fair / Poor, or letters E through P, or green-to-red colors. These grades are not opinions. Behind each cell sits permeation test data: how long the chemical took to break through the glove material, and how fast it passed through afterward. Publishers compress that data into grades using their own thresholds, which is the first thing to understand: there is no universal rating standard. One manufacturer’s “Good” may require 4 hours of breakthrough resistance; another’s may require 1 hour. The same nitrile glove can be “Excellent” in one chart and merely “Good” in another — for the same chemical.
The practical rule follows directly: trust the numbers, use the letters only to shortlist. Any chart worth using publishes (or links to) the underlying breakthrough times in minutes. If a chart gives you colors with no data behind them, it is a marketing document, not a safety document.
The Number Behind Every Cell: Breakthrough Time
The single most important concept behind the grid is chemical glove breakthrough time: the elapsed time between the chemical first contacting the outside of the glove and its molecules being detected inside, measured under standardized test conditions (EN 16523 in Europe, ASTM F739 in the US). Charts compress this into grades because a grid of raw minutes for hundreds of chemicals is unwieldy — but the minutes are what your safety decision actually needs. If your task involves 45 minutes of continuous contact, a glove graded “Good” with a 30-minute breakthrough is the wrong glove, whatever the letter says.
Breakthrough time also has a silent partner: permeation rate, how fast the chemical passes through after breakthrough. Two gloves can share a 60-minute breakthrough and differ tenfold in how much chemical crosses in the following hour. For brief splash contact, breakthrough dominates the decision; for immersion or long contact, rate matters just as much.
What Charts Don’t Show: Degradation
Compatibility grades come from permeation testing on intact material. They say nothing about what the chemical does to the glove physically — swelling it, softening it, making it brittle or tacky. That is degradation, a separate property measured separately (EN 374-4), and it is the most common reason chart-approved gloves fail in the field: the material doesn’t get permeated in the textbook sense, it gets destroyed. A complete specification checks both columns — permeation data and degradation data — and a chart that shows only one is half a chart. Some publishers do include a separate degradation rating; if yours doesn’t, ask for it.
Why “Nitrile Is Good for Solvents” Is Not a Chart
The most dangerous way to read a compatibility chart is at the level of material families. “Nitrile handles oils and solvents” is a generality that collapses on contact with specifics: nitrile resists aliphatic hydrocarbons and oils well, yet acetone and other ketones break through many nitrile gloves in minutes. Formulations also differ between manufacturers — plasticizer packages, curing, and thickness change results — which is why serious charts are published per glove model, not per polymer. The chart’s correct unit of analysis is always this glove, this chemical, this concentration, this temperature.
- Concentration matters: 10% and 96% sulfuric acid are different hazards with different breakthrough profiles; charts are usually built on the neat or specified concentration.
- Mixtures behave unpredictably: a blend can permeate faster than either component alone (“carrier effect”). For mixtures, test data on the mixture itself — or a conservative change-out schedule — is the safe route.
- Temperature accelerates everything: standard tests run near room temperature; hot chemicals can cut breakthrough times dramatically.
The Other Chart on the Wall: EN ISO 374 Types A, B, and C
European gloves carry a second, more formal compatibility language: the EN ISO 374 classification printed under the flask pictogram. It deserves decoding, because it is a test result, not a marketing badge. The standard tests gloves against a reference list of 18 chemicals, each assigned a letter code (A is methanol, K is sodium hydroxide 40%, L is sulfuric acid 96%, and so on). The letters printed under the pictogram are the chemicals that glove was actually tested against — read them and you know exactly which rows of the chart have data behind them.
- Type A: breakthrough of at least 30 minutes against at least 6 of the reference chemicals.
- Type B: breakthrough of at least 30 minutes against at least 3 reference chemicals.
- Type C: breakthrough of at least 10 minutes against at least 1 reference chemical.
Two cautions follow. First, the classification certifies performance against those specific reference chemicals only — a Type A glove has proven nothing about your solvent unless your solvent is on its letter list. Second, the 30-minute threshold for Types A and B is a floor, not a shift length: a glove that breaks through at minute 31 earns the same type as one that lasts 8 hours. The type narrows the field; the underlying breakthrough table — the chart this guide is about — makes the final call.
A worked example shows why the table matters more than the type: one butyl/fluoro-rubber chemical glove, CE certified to EN ISO 374-1 Type A and EN ISO 374-5 (certificate 0598/PPE/25/3427, valid to 2030-05-22), reports breakthrough times over 480 minutes for methanol, acetone, acetonitrile and toluene, over 120 minutes for ethyl acetate, and over 60 minutes for dichloromethane — the same Type A label, six very different wear-time decisions.
How to Use a Compatibility Chart Correctly: Five Steps
- 1. Name the exact chemical. Pull it from the SDS — full name, CAS number, concentration — not the trade name on the drum.
- 2. Find the row for your specific glove model. Not the material family — the model, in the thickness you actually stock.
- 3. Compare breakthrough time to task time. Continuous contact should stay well inside breakthrough — many programs cap wear time at half the measured breakthrough time or less.
- 4. Check degradation. If the chemical degrades the material, downgrade or reject regardless of the permeation grade.
- 5. Write the change-out rule. The chart’s output should become a line in your procedure: glove model, maximum wear duration, replacement trigger. A chart that doesn’t change a procedure changed nothing.
Regulators expect exactly this rigor: OSHA’s hand protection standard, 29 CFR 1910.138, requires employers to select gloves that adequately protect against the specific chemical hazards present — a duty that a generic material chart alone does not discharge.
Need the data behind the letters? Aceppe quotes chemical gloves with manufacturer permeation data for your specific chemical list, not family-level generalities. Send us your SDS list through our contact page and we will build the compatibility shortlist for your process.
🧪 Free Tool: Glove Chemical Compatibility Checker
Check 60 chemicals against 6 glove materials with four-tier ratings — the fastest way to shortlist before you dig into full permeation datasheets. Free, no signup.