Safety Helmet Standards: EN 397 Explained

EN 397 safety helmet standards explained: mandatory impact and penetration tests, optional ratings for cold, heat and electrical work, and reading the marking.

A safety helmet looks like the simplest item in the PPE catalogue: a hard shell, a harness, a chinstrap. The standard behind it is more exacting than the object suggests. EN 397 is the European standard for industrial safety helmets, and it defines precisely what a helmet must survive before it can carry the marking — a 5 kg striker dropped from a metre, a pointed striker aimed at the crown, ten seconds of flame, and a chinstrap that must release before it can strangle. This guide explains the mandatory tests, the optional ratings, how to read the marking, and how EN 397 compares with the US standard.

Construction worker wearing a white industrial safety helmet on a building site
EN 397 defines what a helmet must survive before it can carry the marking.

What EN 397 Covers

EN 397 sets performance requirements for industrial safety helmets used where there is a risk of falling objects or impact to the head: construction sites, factories, warehouses, mining, utilities, and road work. The current widely referenced edition is EN 397:2012+A1:2012, published by the European Committee for Standardization (CEN) and adopted nationally as BS EN 397 in the UK. A helmet certified to EN 397 is a Category II product under the EU PPE Regulation, which means its conformity is assessed by a notified body rather than by the manufacturer’s self-declaration alone, and it carries the CE mark.

Scope matters. EN 397 covers helmets designed primarily for protection against impacts to the top of the head. It is not the standard for climbing-style helmets, which fall under EN 12492 and are tested for side, front, and rear impacts as well as crown impacts, and it is not a bump cap standard — bump caps for protection against minor knocks are covered by EN 812 and offer far less protection. In the United States the equivalent industrial standard is ANSI/ISEA Z89.1, referenced by OSHA for head protection, and a helmet sold globally may carry both markings. The OSHA head protection standard (29 CFR 1910.135) requires employers to provide head protection where there is a risk of head injury from falling or flying objects.

The Mandatory Tests

Every helmet certified to EN 397 must pass all four mandatory tests, carried out after conditioning that includes heat (+50 °C), cold (−20 °C), and artificial ageing under UV light. The conditioning matters: a shell that passes at room temperature and turns brittle in the cold is not a compliant helmet.

Mandatory testMethodPass requirement
Shock absorption5 kg hemispherical striker dropped from 1 m onto the crown (about 49 J)Force transmitted to the headform must not exceed 5 kN
Penetration resistance3 kg pointed striker dropped from 1 m onto the crown (about 29 J)The striker tip must not make contact with the headform
Flame resistanceOuter shell exposed to flame for 10 secondsShell must self-extinguish within 5 seconds of flame removal
Chinstrap anchorageTensile force applied to the strap until the anchorage releasesRelease must occur between 150 N and 250 N

The chinstrap requirement deserves attention because it runs against intuition. A chinstrap that holds too firmly can become a strangulation hazard if it snags on machinery or scaffolding, so EN 397 deliberately requires the anchorage to break away at 150–250 N — enough to keep the helmet on in wind and during normal movement, weak enough to release under a dangerous pull. The standard also requires that the shell or the headband is fitted with a chinstrap or with the means of attaching one, and that any strap supplied is at least 10 mm wide when untensioned.

Optional Ratings: Cold, Heat, Electrical, Molten Metal

Beyond the mandatory tests, EN 397 defines optional performances a manufacturer can claim — and mark — only if the helmet passes the additional test. These options are where most specification mistakes happen: a helmet without them is not defective, but it is the wrong helmet for a site that needs them.

Optional markingMeaningTypical use
−20 °C or −30 °CImpact and penetration performance retained at very low temperatureCold storage, winter outdoor work, high-altitude sites
+150 °CPerformance retained at high temperatureFoundries, hot industrial environments
440 V a.c.Electrical insulation to 440 volts ACElectrical work, utilities (non-vented shells only)
LDLateral deformation — resistance to side compressionConfined spaces, work with side-crush risk
MMMolten metal splash resistanceFoundries, smelting, metal casting

Two practical consequences follow. First, ventilation and electrical insulation conflict: a vented shell cannot carry the 440 V a.c. rating, so a helmet specified for electrical work must be non-vented, and a buyer who orders vented helmets for an electrical crew has specified away the protection. Second, the optional markings must appear on the helmet itself — a supplier’s claim in a catalogue is not a rating. The UK Health and Safety Executive’s guidance on construction head protection stresses the same discipline: helmets must be in good condition, fit properly, be obtained from a reputable supplier, and be replaced if damaged. See the HSE construction PPE guidance on head protection for the regulator’s own checklist.

Reading the Marking

An EN 397 helmet is permanently marked with the standard number, the manufacturer’s name or mark, the model, the year and quarter of manufacture, and the size range, together with any optional ratings claimed. A typical marking reads “EN 397:2012+A1:2012, −20 °C, 440 V a.c.” — and the buyer should check that the marking on the delivered helmet matches the marking in the specification, not just that the helmet looks the same as the sample. The year and quarter of manufacture matter because the shell ages: UV exposure, heat, and solvents degrade the material over time, and the manufacturer’s stated service life runs from the date of manufacture, not from the date of first use.

Buyers should also be aware that the standard is being revised. A 2025 revision of EN 397 introduces Type 1 (crown impact protection) and Type 2 (crown and lateral impact protection) classes, with updated chinstrap release levels for the two types. Helmets certified to the 2012 edition remain in circulation while the revision is adopted, so confirm which edition a supplier’s certificate covers and write that edition into the purchase specification. Our guide to verifying PPE certifications before a bulk order explains how to check the certificate behind any certified helmet, including the notified body and the edition cited.

EN 397 vs ANSI/ISEA Z89.1

Buyers who source for both European and US sites need both standards on the table. ANSI/ISEA Z89.1-2014 is the dominant North American standard and is referenced by OSHA. Its Type I helmets protect against top impact and its Type II helmets protect against top and lateral impact, and it adds electrical classes: Class E (electrical, tested to 20,000 V), Class G (general, tested to 2,200 V), and Class C (conductive, no electrical protection). The impact test caps the peak transmitted force at 4,450 N (1,000 lbf) with the per-group average held to about 3,780 N — a lower force limit than EN 397’s 5 kN, but measured under a different test procedure, so the two numbers cannot be compared directly.

The practical difference is scope: EN 397’s lateral protection is an optional LD claim, while ANSI Type II makes lateral impact a defined type. A buyer whose crews work at height, around moving plant, or in environments with side-impact risk should specify the lateral claim explicitly on either side of the Atlantic — EN 397 with LD, or ANSI Z89.1 Type II — rather than assuming a standard industrial helmet covers it. Where a single helmet must serve both markets, dual-certified models exist, and the specification should list both markings rather than relying on one.

Choosing the Right Helmet for the Job

Selection starts from the hazard assessment, not from the catalogue. The deciding factors are the type of impact risk (falling objects, lateral crush, electrical contact, molten splash), the temperature range, whether the work is at height or in wind, and what other PPE the helmet must work with. That assessment is the document that justifies the specification — which is why a written PPE hazard assessment should come before the order: it records why one crew gets a vented shell and another gets a non-vented 440 V a.c. model.

Shell material is the next decision. High-density polyethylene (HDPE) is the common, economical choice; ABS offers better impact resistance and is often chosen for heavier industrial use; polycarbonate and composite shells appear where higher performance or chemical resistance is needed. The suspension matters as much as the shell: a four-point harness is the minimum, a six-point harness spreads the load better and is more comfortable over a long shift, and a ratchet adjustment lets the wearer tighten the fit with gloves on. Accessories — face shields, earmuffs, headlamps — must be compatible with the specific helmet model, because a clip-on accessory that defeats the shell’s ventilation or interferes with the suspension can void the certification.

Fit is a safety property, not a comfort preference. A helmet that is too loose shifts on impact and can expose the head; a helmet that is too tight is worn pushed back or not at all. The size range on the marking is the check, and the fitting should be tested with the wearer’s other PPE — earmuffs, eye protection, and a respirator — because the helmet, the earmuff seal, and the spectacle arms all compete for the same space around the head.

Inspection, Care and Replacement

A helmet’s protection is not permanent. Inspect before each use: check the shell for cracks, dents, and deep scratches, the harness for fraying and broken cradles, and the chinstrap for wear. Replace immediately after any significant impact, even if the damage is not visible — the shell and harness can be weakened without showing it. Replace also if the shell shows signs of UV degradation, chalking, or chemical attack, and follow the manufacturer’s stated service life from the date of manufacture, not from first use. Storage matters: keep helmets away from direct sunlight, heat, and solvents, and never paint or drill a shell, because paint solvents and holes can degrade the material and void the certification.

Replacement should be a written rule, not a judgement call on site. A helmet that has taken a blow and looks fine stays in circulation only if nobody recorded the blow — which is why incident reporting and a defined replacement trigger belong in the site’s PPE procedure.

Common Buying Mistakes

  • Ordering vented helmets for electrical work. Vents and the 440 V a.c. rating are incompatible. Specify non-vented shells where electrical insulation is required.
  • Accepting a catalogue claim as a rating. Optional ratings count only when they are marked on the helmet and backed by the certificate. Check the marking on delivery.
  • Ignoring the manufacturing date. Service life runs from manufacture, not from first use. Old stock can be out of life before it is worn.
  • Assuming one helmet covers every hazard. EN 397 covers crown impact; lateral, electrical, and molten-metal protection are separate claims that must be specified.
  • Buying on price from an unknown supplier. Counterfeit hard hats are a known problem. Source from a reputable supplier and verify the certificate — the HSE guidance says so explicitly.

Get Samples Matched to Your Site Hazards

If you are specifying safety helmets for your workforce, send us the site hazards, the standards your client requires, and the size range you need. We can recommend helmets against that specification and provide free samples for fit and task trials; the buyer covers shipping. Start with the contact form and include your work areas, electrical and temperature requirements, and quantities, and we will respond with matched options rather than a generic catalogue.

Related Guides

How to Conduct a PPE Hazard Assessment (OSHA Guide) | Safety Footwear Standards: EN ISO 20345 S1–S7 Explained | How to Verify PPE Certifications Before a Bulk Order